Technical features
- Thermal conductivity D-value according to EN 12667: 0,024 W/mK - Core volume weight: + 30 kg/m³
Mechanical performance
- Compressive strength with 10% deformation: CS (10/Y)150 according to EN 826 > 150 kPa (1,5 kg/cm²) - Transformation under the influence of a load: DLT(2)5 according to EN 1605 40 kPa, at 70°C during 168 hours < 5%
Vapour diffusion resistance number µ of the TAUfoam: 50-100
Facing
Pure aluminium + 50µ
Tensile strength perpendicular to surface TR80 according to EN1607: > 80kPa
Long-term water absorption: WL(T)2 according to EN 12087: < 2%
Fire behaviour:
- A1 according to RD 19/12/1997 - Class 1 according to BS 476 Part 7 - Euroclass D s2 d0 according to EN 13501-1
|
Dimensional stability DS(TH)8
according to EN 1604: - Humidity test 48-hours: 70°C, 90% RH - Change in length: < 2% - Change in width: < 2% - Change in thickness: < 6%
Dimensions
- Length: 2500mm - Width: 1200 mm - Thickness : 60 mm and 80 mm on stock - Thickness: 100 mm (or more) on request
Foil RECTIVENT : Width : 1500 mm On roll of 75 m²
Finishing
The boards are provided on all sides with tongue and groove.

Applications
Insulation of pitched roofs fixed on the supporting surface.
Certificates
-
ATG/H 750 KEYMARK 001-BK-514-0004-0022-W002
Standards
The production of these insulation boards is certified to ISO 9001:2000.
Download the technical data of the Powerroof here. |