Technical features
Insulation
D-value: 0.028 W/mK Density: 30 kg/m³ (±2)
Compressive strength
120 kPa (min) 170 kPa (typical) Performance under the influence of an equally distributed load: Class C Deformation under the influence of a load: 40 kPa, at 70°C during 168 hours ≤ 5%
Moisture vapour resistance
40 MNs/g (installed value)
CFC/HCFC content
0%
Facing
Bituminised glass fleece of approx. 400 g/m²
Coefficient of thermal expansion
0.05 mm/mK
Specific heat capacity
1.4 kJ/kgK
Long term water absorption
< 2% (BS EN 12087)
Tensile strength perpendicular to surface
Min. 80 kPa
Fire reaction
Euroclass F (BS EN 13501-1)
Dimensional stability
48-hours humidity test: 70°C, 90% RH (EN 1604) change in length: ≤ 2% change in width: ≤ 2% change in thickness: ≤ 6%
|
Dimensions
slope 1:80 |
1200 x 600 mm |
80 A |

|
80 B |

|
80 C |

|
80 D |

|
80 E |

|
slope 1:60 |
1200 x 600 mm |
60 A |

|
60 B |

|
60 C |

|
60 D |

|
Edge detail
Straight edge
Applications
Creating insulation and falls during new construction and renovation of flat roofs Suitable for use under built-up bituminous felts, single-ply membrane and mastic asphalt waterproofing systems
Remarks
Dry system: no introduction of moisture between existing and new roofing The additional imposed load is reduced to a minimum
Certificates
ATG 1575 ATG/H 707
CEN KEYMARK 001-BK-514-0004-0010-W003 001-BK-514-0004-0011-W003
Standards
Manufactured to BS EN 13165
The production of the boards is certified to ISO 9001:2000
Health & Safety Data
Click here to download the Health & Safety Data Sheet.
|