Technical features
Insulation
D-value: 0.026 W/mK Density: 30 kg/m³ (±2)
Compressive strength
120 kPa (min) 170 kPa (typical)Performance under the influence of an equally distributed load: Class C Deformation under the influence of a load: 40 kPa, at 70°C during 168 hours ≤ 5%
Moisture vapour resistance
15 MNs/g (board only), 40 MNs/g (installed value - bedded in bitumen)
CFC/HCFC content
0%
Facing
Mineral coated and perforated glass fleece of approx. 150g/m²
Coefficient of thermal expansion
0.05 mm/mK
Specific heat capacity
1.4 kJ/kgK
Long term water absorption
< 2% (BS EN 12087)
Tensile strength perpendicular to surface
Min. 80 kPa
Fire reaction
Euroclass E (BS EN 13501-1) Euroclass B s2 d0 (end use on metal deck)
Dimensional stability
48-hours humidity test: 70°C. 90% RH (EN 1604) change in length: ≤ 2% change in width: ≤ 2% change in thickness: ≤ 6%
|
Dimensions
Standard: 1200 x 600 mm Thickness: 30, 40, 50, 60, 70, 80, 90, 100, 110, 120, 130, 140 & 150 mm
Edge detail
Square edge. (Lap joint is available on thicker boards subject to minimum order)
Applications
Flat roof insulation for use under built-up bituminous felts, single-ply membrane (adhered and mechanically fixed) and mastic asphalt waterproofing systems
Certificates
ATG 2262 ATG/H 750 CEN KEYMARK 001-BK-514-0004-0019-W002
Standards
Manufactured to BS EN 13165
The production of the boards is certified to ISO 9001:2000
Health & Safety Data
Click here to download the Health & Safety Data Sheet. |