Technical features
Insulation
D-value: 0.024 W/mK Density: 30 kg/m³ (±2)
Compressive strength
150 kPa (min) 250 kPa (typical)Performance under the influence of an equally distributed load: Class C Deformation under the influence of a load: 40 kPa, at 70°C during 168 hours ≤ 5%
Moisture vapour resistance
100 MNs/g (installed value)
CFC/HCFC content
0%
Facing
Embossed 50µ aluminium
Coefficient of thermal expansion
0.05 mm/mK
Specific heat capacity
1.4 kJ/kgK
Long term water absorption
< 2% (BS EN 12087)
Tensile strength perpendicular to surface
Min. 80 kPa
Fire reaction
A1 (RD 19/12/1997) Class 1 (BS 476, Part 7) FM Approval Class 1 (Factory Mutual Standard 4450) Euroclass D s2 d0 (BS EN13501-1)Euroclass B s2 d0 (end use on metal deck)
Dimensional stability
48-hours humidity test: 70°C. 90% RH (EN 1604) change in length: ≤ 2% change in width: ≤ 2% change in thickness: ≤ 6%
|
Dimensions
Standard: 2500 x 1200 mm Thickness: 30, 40, 50, 60, 70, 75, 80, 90, 100, 110, 120 & 150 mm
Edge detail
Square edge. (Lap joint is available on thicker boards subject to minimum order)
Remarks
On request, and for larger quantities, the board length may be customised to fit the corrugation opening thus avoiding the need to cut the boards to length
Applications
Flat roof insulation for use under mechanically fixed single-ply waterproofing systems (bituminous or synthetic)
Certificates
-
ATG 2262 ATG/H 750
-
CEN KEYMARK 001-BK-514-0004-0021-W002
Standards
Manufactured to BS EN 13165
The production of the boards is certified to ISO 9001:2000
Health & Safety Data
Click here to download the Health & Safety Data Sheet. |