Does Recticel offer a tapered insulation products?
Many flat roofing problems are attributed to ineffective rainwater run-off. This can cause deflection of the roof deck and 'ponding' of rainwater, and have a significant impact on the lifespan of the roof. Recticel's flat roofing tapered insulation division - Gradient - provides bespoke tapered insulation solutions, allowing virtually any fall to be created on either a new or existing roof. A Gradient tapered roof will:
- Improve thermal and acoustic performance
- Minimise ponding and roof loading
- Restrict build-up of rooftop debris
- Reduce the resulting maintenance costs
- Provide a longer, more effective working life
- Aid compliance with Building Regulations
In providing this service, Gradient will work out a detailed roof plan and calculate the exact number of boards required in advance. They work exclusively with Recticel to provide specialist PIR insulation solutions, but are not limited in their choice of materials and can produce specifications that include mineral wool, polystyrene and cork. This enables Gradient to deliver truly unique and bespoke solutions, utilising the best characteristics of all the insulation materials available in the UK today.
FHS: Is there a transition period for projects already underway?
Yes. Transitional arrangements apply until 24 March 2028 for most new homes and until 24 September 2028 for relevant higher-risk building provisions. Projects with a valid building control application submitted before the Future Homes Standard comes into force may continue under the previous standards, provided they meet the applicable commencement requirements.
FHS: What new compliance reporting is introduced?
The updated compliance regime includes design-stage and as-built Building Regulations England Part L (BREL) reports, mandatory photographic evidence of key construction stages, and Home User Guides for homeowners. Together, these requirements increase the amount of documentation needed to demonstrate that the completed building matches its design specification and energy performance assumptions.
How do you calculate a U-value?
A U-value is calculated from the total thermal resistance of a building element, taking into account the different materials and layers within the construction build-up.
The basic principle is:
U-value = 1 ÷ total thermal resistance
Recticel Insulation's online U-value calculator can be used to assess the indicative thermal performance of different construction build-ups without having to calculate each layer manually.
How does insulation contribute to energy efficiency
Insulation reduces the transfer of heat through a building's walls, roofs and floors. This can help buildings retain heat during colder periods and limit heat gains during warmer periods.
High-performance insulation can therefore help reduce the energy required to maintain comfortable indoor temperatures over the lifetime of a building.
How is thermal bridging assessment changing?
Greater emphasis is being placed on the accurate assessment of thermal bridging. Designers are increasingly using calculated psi-values or recognised construction details rather than relying on default thermal-bridging assumptions, as these can make compliance with Part L and the Future Homes Standard more difficult to achieve.
How should I store Recticel Insulation boards?
Our boards are supplied in polythene shrink wrap which is designed for short-term protection only. It is accepted that storing boards indoors is not always possible – when outdoor storage is necessary, boards should be stored clear of the ground, on a level surface, and under cover to protect them from prolonged exposure to moisture, UV light or mechanical damage.
Speak to our technical experts
How thick do I need to insulate?
We recommend that you seek advice from your architect, designer, energy assessor etc. to determine the appropriate insulation thickness. If you already know the desired performance, you can contact our Technical Services team for U-value calculations or look up the required R-value and corresponding thickness in the technical datasheet.
The cleanest energy for heating and cooling, is the energy you do not have to use. That is why we recommend to insulate a flat roof to a higher standard than the minimum requirement. We recommend a minimum of 45 mm Deck-VQ® (Lambda (λ) = 0,009 W/mK) for renovation and 60 mm (Lambda (λ) = 0,008 W/mK) for new build.
Speak with our technical experts
How to install Deck-VQ® vacuum insulation panels?
Deck-VQ® can be applied in warm flat roofs or terraces of a new build and refurbishment projects. Generally speaking the panels are installed over the existing roof covering (refurbishment) or new vapour control layer (new build). The waterproofing system is then applied on top of the insulation and finished in an appropriate manner.
The Deck-VQ® concept is a complete package, designed to limit the risk of damaging the VIP inside during installation.

To take away your concerns, we have included a couple of features and services:
NO drilling allowed? How do I fix Deck-VQ®?
- The PIR protection boards offer compatibility with a variety of adhesives and waterproofing systems*.
- The high density PIR protects the VIP inside from normal physical damage, which allows a ballasted build-up.
NO sawing allowed? How do I cover the complete surface?
- Deck-VQ® panels are available in four standard dimensions (mm x mm): 1200x600 / 1200x300 / 600x600 / 600x300 which make it possible to design an optimal configuration for your project.
- Around details (e.g. corners, edges and roof penetrations) or to fill gaps, we provide PIR insulation in the corresponding thickness.
- Our technical services can provide an optimized layout scheme (like a puzzle) as a guideline for the installation. Do not hesitate to contact us!
Example of a layout scheme:
*We recommend cold adhered single-ply systems (e.g. fleece backed PVC or fleece backed EPDM) or multi-ply bituminous systems (self-adhesive partially bonded base sheet and torch-on cap sheet). For more information on compatibility or support for you project, please contact our technical services.
***UK ONLY: Liquid applied roofing is also possible. In this case, we provide a 3 mm bituminous layer on top.
Contact our vacuum insulation specialist
Is a vapour control layer (VCL) required in a floor insulation application?
In addition to the damp proof membrane (normally a 1200-gauge polythene sheet below the insulation), a 500-gauge polythene VCL should be laid over the insulation. Where a concrete slab or a screed is to be poured on top, the VCL will also protect the foil face of the board from alkalis within the concrete, and stop poured concrete opening board joints and causing a thermal break.